Bharat Chargers
Technical Specifications | ||
---|---|---|
EVFAST Bharat Charger | ||
Model | Bharat AC001 | |
Capacity | 10 kW | |
Input Parameters | Input Voltage (Vac) | 3 Phase, 415 Vac (380 ~ 440 Vac) |
Input Frequency | 50 (±) 1Hz | |
THD | 5% of Nominal Voltage | |
Power Factor | 0.99 (Full Load) | |
Wires | 5 Wires L1, L2, L3, N & PE | |
Output Parameters | Output Voltage (Vac) | Each Output 230 Vac |
Standard Connector | 3 Pin Female Connector | |
No. of Guns / Connector | 3 Output | |
Charging Standard | IEC 60309 | |
Efficiency | ≥ 95% | |
Protection and Safety | Safety Parameters | Over-Voltage, Under-Voltage, Over Current, Short Circuit, Ungrounded, A Type Leakage, OVR, Reverse Connect, Over-Temperature |
User Interface and Control Functions | Display Screen | 4.3" LCD Touch Screen |
Language Supported | English | |
Push Button | Emergency Stop (Red) | |
Visual Indication | Presence of Input Supply, Error Indicator, State of Charge | |
User Authentication | RFID, QR, AppBased | |
Payment | RFID Card, Wallet, App Wallet | |
Communication | Between EV Charger and EV | As Per BEVC-AC001 |
Between EV and Central Server | OCPP 1.6 or Above Ethernet, 2G/3G/4G or Wireless | |
Mechanical | Protection | IP 54 |
Cooling | Natural Cooling | |
Charging Cable Length | No Wire | |
Operating Temperature | (-20~60°C) | |
Storage Temperature | (-20~60°C) | |
Humidity (Non Condensing) | 5%~95% (Non-Condensing) | |
Altitude | ≤ 2000 m |