Technical Specifications
EVFAST Bharat Charger
Model Bharat DC002-DG
Capacity 30 kW
Input Parameters Input Voltage (Vac) 3 Phase, 415 Vac (380 ~ 440 Vac)
Input Frequency 50 (±) 1Hz
THD 5% of Nominal Voltage
Power Factor 0.99 (Full Load)
Wires 5 Wires L1, L2, L3, N & PE
Output Parameters Output Voltage (Vac) 40 ~ 100 Vdc
Standard Connector GB/T
No. of Guns / Connector Dual Gun
Charging Standard GB/T 20234.3
Efficiency ≥ 95%
Protection and Safety Safety Parameters Over-Voltage, Under-Voltage, Over Current, Short Circuit, Ungrounded, A Type Leakage, OVR, Reverse Connect, Over-Temperature
User Interface and Control Functions Display Screen 7" LCD Touch Screen
Language Supported English
Push Button Emergency Stop (Red)
Visual Indication Presence of Input Supply, Error Indicator, State of Charge
User Authentication RFID, QR, AppBased
Payment RFID Card, Wallet, App Wallet
Communication Between EV Charger and EV CAN Based Communication As Per AIS 138-2
Between EV and Central Server OCPP 1.6 or Above Ethernet, 2G/3G/4G or Wireless
Mechanical Protection IP 54
Cooling Forced Air Cooling
Charging Cable Length 5 Meter
Operating Temperature (-20~60°C)
Storage Temperature (-20~60°C)
Humidity (Non Condensing) 5%~95% (Non-Condensing)
Altitude ≤ 2000 m