DC Chargers
Technical Specifications | ||
---|---|---|
EVFAST Ultra | ||
Model | Ultra - Peak | |
Capacity | 142 kW | |
Input Parameters | Input Voltage (V) | 380 ~ 440 V |
Input Frequency | 50 (±) 1Hz | |
THD | 5% of Nominal Voltage | |
Power Factor | 0.99 (Full Load) | |
Wires | 3 Phase, 5 Wires L1, L2, L3, N & PE | |
Output Parameters | DC Output 1 | CCS-2, 60 kW |
DC Output 2 | CHAdeMO, 60 kW | |
Output Voltage (Vac) | CCS 2 (200-500 Vdc), CHAdeMO (50-500 Vdc), Type 2 (230 Vac) | |
Standard Connector | CCS 2 + CHAdeMO + Type 2 | |
No. of Guns / Connector | Triple Gun | |
Charging Standard | CCS 2 + CHAdeMO + Type 2 IEC 62196-2 | |
Efficiency | ≥ 95% | |
Protection and Safety | Safety Parameters | Over-Voltage, Under-Voltage, Over Current, Short Circuit, Ungrounded, A Type Leakage, OVR, Reverse Connect, Over-Temperature |
User Interface and Control Functions | Display Screen | 7" LCD Touch Screen |
Language Supported | English | |
Push Button | Emergency Stop (Red) | |
Visual Indication | Presence of Input Supply, Error Indicator, State of Charge | |
User Authentication | RFID, QR, AppBased | |
Payment | RFID Card, Wallet, App Wallet | |
Communication | Between EV Charger and EV | CAN (CHAdeMO), PLC (CCS-2) & Type 2 AC As Per IEC 61851-1 |
Between EV and Central Server | OCPP 1.6 or Above Ethernet, 2G/3G/4G or Wireless | |
Mechanical | Protection | IP 54 |
Cooling | Forced Air Cooling | |
Charging Cable Length | 5 Meter | |
Operating Temperature | (-20~60°C) | |
Storage Temperature | (-20~60°C) | |
Humidity (Non Condensing) | 5%~95% (Non-Condensing) | |
Altitude | ≤ 2000 m |